3.3.Enable and save new parameter settings Ø  ”Submit” Save the new settings to eCOV-110 and restart the unit to enable the settings. Ø  ”Cancel” Reset all the changes back to the value when the page was loaded.
4.  Command Mode eCOV-110 parameter settings can be changed through serial port or network interface by    command mode, the users can easily complete the parameter changes of eCOV-110 with simple commands. This function is designed mainly for use when eCOV-110 has already connected to the   serial port of the application equipment and still needs to be configured. The users can do all the parameter settings on  eCOV-110 through the serial port of the application equipment without connecting eCOV-110 directly to the Host PC. Thus when eCOV-110 is used on the end-user side, if there is any problem on the setting or to prevent end-users making any parameter change to eCOV-110 is desired, all can be done by the small utility built inside the eCOV-110 unit. Also, the system administrator can use the command mode to make all the parameter   settings on eCOV-110 through HyperTerminal or telnet program. 4.1.Network end Command Mode (TCP Port No 5001) Ø  HyperTerminal select ”TCP/IP (Winsock)” Ø  Input the eCOV-110 IP address and eCOV-110 specific Port No. 5001   Ø  Input Command “$LOG”
Ø  eCOV-110 will then treat all the input data as input Commands but not for data   transferring, and all the communications on the network side will be stopped including    Web Console.   4.2.Command Mode Usage Ø  Command Format [Start Code][Command ][OP Code][OP Code Parameters][End Code] ‘$ ’ : Start Code(1 byte) ‘Command’:    load or change settings,’S’ for change settings,’G’ for load current setting ‘OP Code’  : associated operation setting code, for example ”LI” for LAN IP Address ‘OP Code Parameters’:    When Command is set to ’S’, each OP Code will need to apply    with a parameter. ‘End Code’:    Each command’s end code will be the two Byte code”0x0d0x0a” (CRLF)   For example:   - Load SE-100 LAN IP address: $GLI(CRLF) - Set SE-100 LAN Subnet Mask: $SLN255.255.255.0(CRLF) Ø  Reply Message Format Reply message when Command is correct: l  When Command is ’S’ for changing the setting   : [Start Code][Command][OK Message][End Code] ‘Start Code’:   Always start with ”%” ‘Command’:    If operated correctly, the reply is “ANS”      ‘OK Message’: “OK”  When Command is ’S’ changing the setting   : ‘End Code’:    Always two Byte”0x0d0x0a” (CRLF) For example: Reply for setting SE-100 LAN IP address: %ANSOK(CRLF) l  When Command is ’G’ for loading the setting   :
[Start Code][Command] [Reply Message][End Code] ‘Start Code’:    Always start with ”%” ‘Command’: Command’: f operated correctly, the reply is “ANS” ‘‘Reply Message’:     The actual parameter settings loaded from eCOV-110. ‘End Code’:    Always two Byte”0x0d0x0a” (CRLF) For example: Reply for loading the setting of SE-100 LAN Subnet)   Mask: %ANS255.255.255.0(CRLF) Reply message when Command is not correct: [Start Code][Error Message][End Code] ‘Start Code’:    Always ”%” ‘Error Message’: “ERR”   ‘End Code’:    Always two Byte”0x0d0x0a” (CRLF) Always: %ERR(CRLF) 4.3.OP Code and OP Code Parameters OP Code OP Code Description Available Command OP Code Parameters Basic Information BM Product Name G only Always “eCOV-110” BN Product Alias S, G Any character, max. length 14 byte   BP Password Setting S only Any character, max. length 8 byte BV Firmware Version G only Format:: x.xx.xxx LAN Settings LI IP Address S, G Format:xxx.xxx.xxx.xxx LN Subnet Mask S, G Format:xxx.xxx.xxx.xxx LG Gateway S, G Format:xxx.xxx.xxx.xxx LC IP Obtaining Method S, G 0 : static IP 1 : DHCP LM MAC Address G only Format: xx:xx:xx:xx:xx:xx LS Network(LAN) G only 3 reply messages contains: link Fail link ok, 100M link ok, 10M Network Settings OM Operation Mode G only “TS” only, for TCP Server OC Enable/Disable Timeout S, G Available parameter: “AC”: always connect “TO”: Enable Timeout,
must accompany with      OP Code ”OU” OU Timeout value,    unit: minutes S, G Available range: 1~99   Must accompany with   OP Code ”OC” or OP Code ”OU” OD Data Packing   Method S, G Setting format: 3 digits number Centesimal value:Delimiter Decimal value: Timeout    Unit value: length 1: for Enable 0: for Disable Accompany with OP Code: “OS”,   OT”, “OL” OS Delimiter Setting S, G Can set with 2 bytes Hex code Accompany with OP Code: “OD” OT Timeout Setting,   Unit: ms S, G Available range: 1~65535   Accompany with OP Code: “OD” OL Packet Length    Setting, Unit: Byte S, G Available range: 1~1024   Accompany with OP Code: “OD” OF Enable/Disable   IP Filtering S, G 0: For Disable 1: For Enable Accompany with OP Code “OI” OI IP Filtering Range   S, G Format:ip1:ip2 ip1: Start IP address ip2: End IP address Accompany with OP Code “OF” OA TCP Alive Check Timeout Setting, Unit: minutes S, G Available range: 0~99 When set to 0, it means not enable TCP Alive Check TCP Server Transfer Settings  VP TCP Server Local Listen Port S, G Available range:1~65535 TCP Client Transfer Settings